High Voltage High-altitude Electromagnetic Pulse (HEMP) filters are designed to protect sensitive electronics equipment from EMI and during hazardous transient conditions. These filters are employed to absorb a potentially destructive overshoot voltage and will also help meet the requirements of MIL-STD-188-125.
Current (A) | Length | Width | Height | Input | Output |
---|---|---|---|---|---|
6 | 9 | 4.5 | 4.25 | IEC 320-C14 | 10-32 |
16 | 9 | 4.5 | 4.25 | IEC 20 | 10-32 |
30 | 10 | 4.5 | 4.25 | NEMA L6-30P | 10-32 |
Part Number | Voltage (AC, 50/60 Hz) |
Current (A) | Leak (ma) | IR | DWV (VDC) | VD | Operating Temp | Storage Temp | Pass |
---|---|---|---|---|---|---|---|---|---|
52-1700-101 | 24 VDC | 6 | 0 | 1 G | 2250 | < 1% | -40 / + 65C | -55 / +105C | <2A |
52-1700-102 | 24 VDC | 16 | 0 | 1 G | 2250 | < 1% | -40 / + 65C | -55 / +105C | <2A |
52-1700-103 | 24 VDC | 30 | 0 | 1 G | 2250 | < 1% | -40 / + 65C | -55 / +105C | <2A |
52-1700-201 | 48 VDC | 6 | 0 | 1 G | 2250 | < 1% | -40 / + 65C | -55 / +105C | <5A |
52-1700-202 | 48 VDC | 16 | 0 | 1 G | 2250 | < 1% | -40 / + 65C | -55 / +105C | <5A |
52-1700-203 | 48 VDC | 30 | 0 | 1 G | 2250 | < 1% | -40 / + 65C | -55 / +105C | <5A |
52-1700-301 | 72 VDC | 6 | 0 | 1 G | 2250 | < 1% | -40 / + 65C | -55 / +105C | <5A |
52-1700-302 | 72 VDC | 16 | 0 | 1 G | 2250 | < 1% | -40 / + 65C | -55 / +105C | <5A |
52-1700-303 | 72 VDC | 30 | 0 | 1 G | 2250 | < 1% | -40 / + 65C | -55 / +105C | <5A |
52-1700-402 | 125 VAC | 6 | 150 | 1 G | 2250 | < 1% | -40 / + 65C | -55 / +105C | <2A |
52-1700-404 | 125 VAC | 16 | 150 | 1 G | 2250 | < 1% | -40 / + 65C | -55 / +105C | <5A |
52-1700-406 | 125 VAC | 30 | 150 | 1 G | 2250 | < 1% | -40 / + 65C | -55 / +105C | <5A |
52-1700-502 | 250 VAC | 6 | 350 | 1 G | 2250 | < 1% | -40 / + 65C | -55 / +105C | <2A |
52-1700-504 | 250 VAC | 16 | 350 | 1 G | 2250 | < 1% | -40 / + 65C | -55 / +105C | <5A |