Home | | | | | High Frequency Attenuation

High Frequency Attenuation

60-BHP Series

Ideally suited for products that must conform to FCC part 15 regulations. Metal cased filter offers high performance. Meets overvoltage of IEC 664 category II and complies with IEC 950. Solder-lug, fast-on tab styles available. PCB mounting minimizes space and provides economical installation. Excellent filtering characteristics for high frequencies.

  • Ideally suited for products that must conform to FCC part 15 regulations
  • Metal cased filter offers high performance
  • Meets overvoltage of IEC 664 category II and complies with IEC 950
  • Solder-lug, fast-on tab styles available
  • PCB mounting minimizes space and provides economical installation
  • Excellent filtering characteristics for high frequencies
  • Earth coil standard
  • Operating temperature: -25°C to +85°C, including temperature rise
  • Digital equipment
  • Personal computers and peripherals
  • Measuring instruments
  • Monitor and display units

UL Icon 60-BHP Series

   
Part number Rated Voltage (@ 50/60Hz) Rated Current Leakage Current (Max.) Capacitance Inductance (L1) Inductance (L2) Temperature Rise (Max.)
CY CX
*60-BHP-010-3-11 250VAC 1A 0.35mA 2200pF 0.1µF±20% 6mH 18.3 µH 30°C
*60-BHP-010-3-4 250VAC 1A 0.35mA 2200pF .047µF±20% 6mH 18.3 µH 30°C
*60-BHP-010-5-11 250VAC 1A 0.50mA 3300pF 0.1µF±20% 6mH 18.3 µH 30°C
*60-BHP-010-5-4 250VAC 1A 0.50mA 3300pF .047µF±20% 6mH 18.3µH 30°C
*60-BHP-020-3-11 250VAC 2A 0.35mA 2200pF 0.1µF±20% 2.4mH 18.3µH 30°C
*60-BHP-020-3-4 250VAC 2A 0.35mA 2200pF .047µF±20% 2.4mH 18.3µH 30°C
*60-BHP-020-5-11 250VAC 2A 0.50mA 3300pF 0.1µF±20% 2.4mH 18.3µH 30°C
*60-BHP-020-5-4 250VAC 2A 0.50mA 3300pF .047µF±20% 2.4mH 18.3µH 30°C
*60-BHP-030-3-11 250VAC 3A 0.35mA 2200pF 0.1µF±20% 1.2mH 18.3µH 30°C
*60-BHP-030-3-4 250VAC 3A 0.35mA 2200pF .047µF±20% 1.2mH 18.3µH 30°C
*60-BHP-030-5-11 250VAC 3A 0.50mA 3300pF 0.1µF±20% 1.2mH 18.3µH 30°C
*60-BHP-030-5-4 250VAC 3A 0.50mA 3300pF .047µF±20% 1.2mH 18.3µH 30°C
*60-BHP-060-3-11 250VAC 6A 0.35mA 2200pF 0.1µF±20% 0.53mH 18.3µH 45°C
*60-BHP-060-3-4 250VAC 6A 0.35mA 2200pF .047µF±20% 0.53mH 18.3µH 45°C
*60-BHP-060-5-11 250VAC 6A 0.50mA 3300pF 0.1µF±20% 0.53mH 18.3µH 45°C
*60-BHP-060-5-4 250VAC 6A 0.50mA 3300pF .047µF±20% 0.53mH 18.3µH 45°C

*UL approved

Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 50g
Input: Compatible with IEC-320