Home | | | | | Bolt-in Rear Terminals for General Purpose

Bolt-in Rear Terminals for General Purpose

10-BPF Series

These power entry modules use an IEC connector that meets most safety standards.  Its metal case offers high performance and it also has a compact design.  This product will meet the overage voltage of IEC 664 category II and also complies with IEC 950. Ideally suited for products that must conform to FCC part 15 regulations.

  • Ideally suited for products that must conform to FCC part 15 regulations
  • Metal cased miniature filter offers high performance
  • Meets over voltage of IEC 664 category II and complies with IEC 950
  • Uses IEC connector that meets most safety standards
  • Operating temperature: -25°C to +70°C including temperature rise
  • Compact configuration
  • Digital equipment
  • Personal computers and peripherals
  • Measuring instruments
  • Monitor and display units

UL Icon 10-BPF Series

   
Part number Rated Voltage
(@ 50/60Hz)
Rated Current Leakage
Current
(Max.)
Capacitance Inductance
(L1)
**Circuit Diagram Temperature
Rise (Max.)
CY CX
*10-BPF-001-5-A 120/250VAC 1A 0.50mA 3300pF  2200pF  3.0mH 1 30°C
*10-BPF-001-5-C 120/250VAC 1A 0.50mA 3300pF  2200pF  3.0mH 1 30°C
*10-BPF-003-5-A 120/250VAC 3A 0.50mA 3300pF  0.01µF 1.5mH 1 30°C
*10-BPF-003-5-C 120/250VAC 3A 0.50mA 3300pF  0.01µF 1.5mH 1 30°C
10-BPF-003-5-D 120/250VAC 3A 0.50mA 4700pF  0.01µF 1.5mH 2 30°C
*10-BPF-006-5-A 120/250VAC 6A 0.50mA 3300pF  0.01µF 0.5mH 1 30°C
*10-BPF-006-5-C 120/250VAC 6A 0.50mA 3300pF  0.01µF 0.5mH 1 30°C
10-BPF-010-5-A 120/250VAC 10A 0.50mA 3300pF 0.01µF 0.5mH 1 30°C

*UL approved

**Circuit diagrams are at the top of the page. Click to see the full image.

Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 45g
Input: Compatible with IEC-320