Home | | | | | Fuse Filtered for General Purpose

Fuse Filtered for General Purpose

64-65-BFF/BFS Series

Fuse Filtered Power Entry Modules provide effective EMI suppression of common and differential mode. North American and Metric fuse holders available. Suitable for products that must conform to FCC and FTZ requirements. Meets overvoltage category II of IEC 664 and complies with IEC 950. Fast-on terminals or solder lug terminals. The metal case provides effective EMI shielding.

  • North American and Metric fuse holders available
  • Fuse holder provides effective EMI suppression of common and differential mode
  • Suitable for products that must conform to FCC and FTZ requirements
  • Meets overvoltage category II of IEC 664 and complies with IEC 950
  • Fast-on terminals or solder lug terminals
  • The metal case provides effective EMI shielding
  • Operating temperature: -25°C to +85°C including temperature rise
  • Digital equipment
  • Electronic equipment
  • Personal computers and peripherals
  • Measuring and testing instruments
  • Telecommunications equipment

UL Icon Fast-on Terminals, 64-65-BFF Series

Part number Rated Voltage
(@ 50/60Hz)
Rated Current Leakage
Current
(Max.)
Capacitance Inductance (L1) Temperature
Rise (Max.)
CY CX
*64-BFF-020-3-11 250VAC 2A 0.35mA 2200pF ±20% 0.1µF 6.5mH 40°C
*64-BFF-020-5-11 250VAC 2A 0.50mA 3300pF ±20% 0.1µF 6.5mH 40°C
*64-BFF-020-3-12 250VAC 2A 0.35mA 2200pF ±20% 0.22µF 6.5mH 40°C
*64-BFF-020-5-12 250VAC 2A 0.50mA 3300pF ±20% 0.22µF 6.5mH 40°C
*64-BFF-040-3-11 250VAC 4A 0.35mA 2200pF ±20% 0.1µF 4.2mH 45°C
*64-BFF-040-5-11 250VAC 4A 0.50mA 3300pF ±20% 0.1µF 4.2mH 45°C
*64-BFF-040-3-12 250VAC 4A 0.35mA 2200pF ±20% 0.22µF 4.2mH 45°C
*64-BFF-040-5-12 250VAC 4A 0.50mA 3300pF ±20% 0.22µF 4.2mH 45°C
*64-BFF-060-3-11 250VAC 6A 0.35mA 2200pF ±20% 0.1µF 1.6mH 45°C
*64-BFF-060-5-11 250VAC 6A 0.50mA 3300pF ±20% 0.1µF 1.6mH 45°C
*64-BFF-060-3-12 250VAC 6A 0.35mA 2200pF ±20% 0.22µF 1.6mH 45°C
*64-BFF-060-5-12 250VAC 6A 0.50mA 3300pF ±20% 0.22µF 1.6mH 45°C
*65-BFF-020-3-11 125VAC 2A 0.20mA 2200pF ±20% 0.1µF 6.5mH 40°C
*65-BFF-020-5-11 125VAC 2A 0.25mA 3300pF ±20% 0.1µF 6.5mH 40°C
*65-BFF-020-3-12 125VAC 2A 0.20mA 2200pF ±20% 0.22µF 6.5mH 40°C
*65-BFF-020-5-12 125VAC 2A 0.25mA 3300pF ±20% 0.22µF 6.5mH 40°C
*65-BFF-040-3-11 125VAC 4A 0.20mA 2200pF ±20% 0.1µF 4.2mH 45°C
*65-BFF-040-5-11 125VAC 4A 0.25mA 3300pF ±20% 0.1µF 4.2mH 45°C
*65-BFF-040-3-12 125VAC 4A 0.20mA 2200pF ±20% 0.22µF 4.2mH 45°C
*65-BFF-040-5-12 125VAC 4A 0.25mA 3300pF ±20% 0.22µF 4.2mH 45°C
*65-BFF-060-3-11 125VAC 6A 0.20mA 2200pF ±20% 0.1µF 1.6mH 45°C
*65-BFF-060-5-11 125VAC 6A 0.25mA 3300pF ±20% 0.1µF 1.6mH 45°C
*65-BFF-060-3-12 125VAC 6A 0.20mA 2200pF ±20% 0.22µF 1.6mH 45°C
*65-BFF-060-5-12 125VAC 6A 0.25mA 3300pF ±20% 0.22µF 1.6mH 45°C

*UL approved

Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 78g
Input: Compatible with IEC-320

 

 

UL Icon Solder Lug Terminals, 64-65-BFS Series

Part number Rated Voltage
(@ 50/60Hz)
Rated Current Leakage
Current
(Max.)
Capacitance Inductance (L1) Temperature
Rise (Max.)
CY CX
*64-BFS-020-3-11 250VAC 2A 0.35mA 2200pF ±20% 0.1µF 6.5mH 40°C
*64-BFS-020-5-11 250VAC 2A 0.50mA 3300pF ±20% 0.1µF 6.5mH 40°C
*64-BFS-020-3-12 250VAC 2A 0.35mA 2200pF ±20% 0.22µF 6.5mH 40°C
*64-BFS-020-5-12 250VAC 2A 0.50mA 3300pF ±20% 0.22µF 6.5mH 40°C
*64-BFS-040-3-11 250VAC 4A 0.35mA 2200pF ±20% 0.1µF 4.2mH 45°C
*64-BFS-040-5-11 250VAC 4A 0.50mA 3300pF ±20% 0.1µF 4.2mH 45°C
*64-BFS-040-3-12 250VAC 4A 0.35mA 2200pF ±20% 0.22µF 4.2mH 45°C
*64-BFS-040-5-12 250VAC 4A 0.50mA 3300pF ±20% 0.22µF 4.2mH 45°C
*64-BFS-060-3-11 250VAC 6A 0.35mA 2200pF ±20% 0.1µF 1.6mH 45°C
*64-BFS-060-5-11 250VAC 6A 0.50mA 3300pF ±20% 0.1µF 1.6mH 45°C
*64-BFS-060-3-12 250VAC 6A 0.35mA 2200pF ±20% 0.22µF 1.6mH 45°C
*64-BFS-060-5-12 250VAC 6A 0.50mA 3300pF ±20% 0.22µF 1.6mH 45°C
*65-BFS-020-3-11 125VAC 2A 0.20mA 2200pF ±20% 0.1µF 6.5mH 40°C
*65-BFS-020-5-11 125VAC 2A 0.25mA 3300pF ±20% 0.1µF 6.5mH 40°C
*65-BFS-020-3-12 125VAC 2A 0.20mA 2200pF ±20% 0.22µF 6.5mH 40°C
*65-BFS-020-5-12 125VAC 2A 0.25mA 3300pF ±20% 0.22µF 6.5mH 40°C
*65-BFS-040-3-11 125VAC 4A 0.20mA 2200pF ±20% 0.1µF 4.2mH 45°C
*65-BFS-040-5-11 125VAC 4A 0.25mA 3300pF ±20% 0.1µF 4.2mH 45°C
*65-BFS-040-3-12 125VAC 4A 0.20mA 2200pF ±20% 0.22µF 4.2mH 45°C
*65-BFS-040-5-12 125VAC 4A 0.25mA 3300pF ±20% 0.22µF 4.2mH 45°C
*65-BFS-060-3-11 125VAC 6A 0.20mA 2200pF ±20% 0.1µF 1.6mH 45°C
*65-BFS-060-5-11 125VAC 6A 0.25mA 3300pF ±20% 0.1µF 1.6mH 45°C
*65-BFS-060-3-12 125VAC 6A 0.20mA 2200pF ±20% 0.22µF 1.6mH 45°C
*65-BFS-060-5-12 125VAC 6A 0.25mA 3300pF ±20% 0.22µF 1.6mH 45°C

*UL approved

Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 78g
Input: Compatible with IEC-320