High Voltage High-altitude Electromagnetic Pulse (HEMP) filters are designed to protect sensitive electronics equipment from EMI and during hazardous transient conditions. These filters are employed to absorb a potentially destructive overshoot voltage and will also help meet the requirements of MIL-STD-188-125.

Download the EMP/HEMP Filters Whitepaper

  • Insulation resistance, DWV tested prior to discharge resistor and MOV installation
  • Temperature rise is less than 25°C
  • Filters rated for 6A, 16A, and 30A, additionally meet modified E3 pulse test
  • Meets Mil-STD-188-125, E1 and E2 pulse requirements
  • Custom designs available
  • Commercial and industrial infrastructure
  • Ground-based applications
  • Radars
  • Airborne communication systems
  • Federal power grids
Current (A) Length Width Height Input Output
6 9 4.5 4.25 IEC 320-C14 10-32
16 9 4.5 4.25 IEC 20 10-32
30 10 4.5 4.25 NEMA L6-30P 10-32
Part Number Voltage
(AC, 50/60 Hz)
Current (A) Leak (ma) IR DWV (VDC) VD Operating Temp Storage Temp Pass
52-1700-101 24 VDC 6 0 1 G 2250 < 1% -40 / + 65C -55 / +105C <2A
52-1700-102 24 VDC 16 0 1 G 2250 < 1% -40 / + 65C -55 / +105C <2A
52-1700-103 24 VDC 30 0 1 G 2250 < 1% -40 / + 65C -55 / +105C <2A
52-1700-201 48 VDC 6 0 1 G 2250 < 1% -40 / + 65C -55 / +105C <5A
52-1700-202 48 VDC 16 0 1 G 2250 < 1% -40 / + 65C -55 / +105C <5A
52-1700-203 48 VDC 30 0 1 G 2250 < 1% -40 / + 65C -55 / +105C <5A
52-1700-301 72 VDC 6 0 1 G 2250 < 1% -40 / + 65C -55 / +105C <5A
52-1700-302 72 VDC 16 0 1 G 2250 < 1% -40 / + 65C -55 / +105C <5A
52-1700-303 72 VDC 30 0 1 G 2250 < 1% -40 / + 65C -55 / +105C <5A
52-1700-402 125 VAC 6 150 1 G 2250 < 1% -40 / + 65C -55 / +105C <2A
52-1700-404 125 VAC 16 150 1 G 2250 < 1% -40 / + 65C -55 / +105C <5A
52-1700-406 125 VAC 30 150 1 G 2250 < 1% -40 / + 65C -55 / +105C <5A
52-1700-502 250 VAC 6 350 1 G 2250 < 1% -40 / + 65C -55 / +105C <2A
52-1700-504 250 VAC 16 350 1 G 2250 < 1% -40 / + 65C -55 / +105C <5A